Request a Quote

High & Low Temperature Chamber

High & Low Temperature Chamber can realize both high and low temperature test.

It can continuously run for long time.

Controller display easy to understand and operate.

Low Temperature Chamber.jpg 

 

Model

Size (cm) (D×W×H)

Temperature

Power

Test area size

Capacity

External size

Range

Fluctuation

Change rate

WD101

47×50×60

141L

88×68×124

- 12~100 or   150

±0.5

Heating:

3~5/min

 

Cooling:

0.8~2.5/min

2.0Kw

WD102

60×55×75

248L

100×68×155

2.0Kw

WD105

70×80×90

500L

136×138×186

2.5Kw

WD110

100×100×100

1000L

163×140×198

2.5Kw

WD201

47×50×60

141L

88×68×124

- 22~100 or   150

±0.5

2.0Kw

WD202

60×55×75

248L

100×68×155

2.0Kw

WD205

70×80×90

500L

136×138×186

3.5Kw

WD210

100×100×100

1000L

163×140×198

3.5Kw

WD401

45×50×60

135L

105×89×150

- 40~100 or   150

±0.5

4.0Kw

WD402

50×60×75

225L

109×99×165

4.0Kw

WD405

70×80×90

500L

133×122×190

4.5Kw

WD410

100×100×100

1000L

163×140×198

5.0Kw

WD501

45×50×60

135L

105×89×150

-   50~100 or 150

±0.5

5.0Kw

WD502

50×60×75

225L

109×99×165

5.5Kw

WD505

70×80×90

500L

133×122×190

5.5Kw

WD510

100×100×100

1000L

163×140×198

6.0Kw

WD701

45×50×60

135L

105×89×150

- 70~100 or   150

±0.5

5.0Kw

WD702

50×60×75

225L

109×99×165

5.0Kw

WD705

70×80×90

500L

133×122×190

6.0Kw

WD710

100×100×100

1000L

163×140×198

8.0Kw



External material

Printed cold-rolled steel plate

Test area material

SUS304 stainless steel

Insulation material

Super glass cotton

Seal material

Resistant-to-high-temperature silicone rubber


Controller

 FUJI temperature controller with PID imported from Japan

Work mode

Fix and Programmable

Other electric parts

SIEMENS and Omron relays


Compressor

France TECUMSEH compressor or

 U.S. Copeland Emerson compressor

                                             EMERSON THCUMN.png

Cooling mode

Air cooling

Condenser /  Evaporator

Condenser/Evaporator

Other cooling parts

expansion relief valve, 

                                                     electromagnetic control valve, 

                                                      drying filter, pressure controller 


Heater

Nickel-chromium alloy heating wire, and electric relay with over-heat protection

Sensor

Pt100 platinum resistance temperature sensor

Air circulation

Stainless steel long-axial fan compulsory   circulation


Safety parts

Over-heat protection, Over-load of fan protection, Over-load of compressor, 

             Short-circuit  protection, Lack phrase protection, Ground protection

Other structure parts

φ50mm port hole 2 levels of stainless steel tryDefrosting windowLight

Power supply

220±22V, 50~60Hz  or  380±38V, 50~60Hz

 


INQUIRY

Top